Other Products


Following tables are intended as a guide only, for the use of designers in developing concepts. Users should contact the panel manufacturer for further information.

Table A – Thermal Resistance

Thickness (mm)

50

75

100

150

200

R Value (m2 k/w)

1.32

1.97

2.63

3.95

5.62

Note: In choosing panel thickness, structural capacity should also be considered.

Table B – Panel Weights

Econotil

Thickness (mm)

50

75

100

150

200

Weight (kg/m2)

9.6

10.0

10.4

11.2

12.0

Econodeck

Thickness (mm)

75

100

125

150

200

Weight (kg/m2)

10.2

10.6

11.0

11.4

12.2

Note: Panel weights may be subject to minimal variance according to styrene density.

Table C - Wall Panel Spans for typical wind loads

Thickness (mm)

75

100

125

150

200

Span (mm)
  Protected and/or Urban
  Areas

4500

5000

6000

6500

 

  Partly Exposed

4000

4500

5500

6000

7000

  Fully Exposed
3500
4500
5000
5500
6000

Note: Based on a building height of 6 metres, 41 metre per second wind seed. Figures allow for local pressure co-efficient (AS1170.2).

Table D – Ceiling / Roof Spans

Thickness (mm)
50
75
100
150
200

Span (mm)

1

2150

3050

4150

5050

5500

2

2550

3650

4500

5500

6000

3

3400

4000

4800

6000

6500

Note:
 1- Ceiling panels supported at 3 points or less across their span.
 2- Ceiling panels supported at 4 equal points or more across their span.
 3- Non-accessible ceilings or ceiling spaces with less than 1.2m headroom.

Table E – Polystyrene Floor Insulation Compressive Strength

Class
SL
S
M
H
VH

Density (kg/m3)

13

15

20

25

30

Comp. Strength (Kpa)

70

85

105

135

165

Note: At 10% deformation as described in AS 1366 Pt3 1992.

Table F – Early Fire Hazard Properties

Ignitability Index

0

Range 0-20

Spread of Flame Index

0

Range 0-10

Heat Evolved Index

0

Range 0-10

Smoke Developed Index

2

Range 0-10

Note: Results are obtained from Tests in Accourdance with AS 1530 Pt3 1982.

Table G - Al-Rashed Expanded Polystyrene / Physical & Mechanical Properties

Property

Test Method

Unit

Limit

Molded Density

DIN 53420

Kg/m3

16    35

Thermal Conductivity

DIN 52612

W/mkoo

0.038  0.037

Water Vapor Permeability Index 23oC/85% R.H. Water Vapor Diffusion Resistance Factor (u)

DIN 53429

Ug/m25

300   200

Minimum Compression Resistance for 10% Deformation
DIN 53421
Kpa
90   170

Flexural Strength at Break

DIN 53423

Kpa

230   340

Maximum Temperature
for a Deformation

DIN 53424

oC

100   100

Fire Classification

DIN 4102

Bldg. Material class:non-
ombustible



Copyright © 2001 Al-Rashed Polystyrene. All rights reserved.

Al-Rashed Polystyrene Products Factory Al-Rashed Polystyrene Products Factory